Estimasi Dosis Efektif dan Efek Stokastik (Kanker dan Hereditas) pada Pemeriksaan CT-Scan Abdomen dan Toraks dengan Media Kontras
Abstract
Full Text:
PDFReferences
ICRP. The 2007 Recommendations of the international commission on radiological protection, ICRP publication 103. ICRP. 2007;37:2-4. www.mdpi.com/journal/diagnostics%0Ahttp://www-pub.iaea.org/MTCD/publications/PDF/Pub1609_web.pdf%5Cnhttp://www.vomfi.univ.kiev.ua/assets/files/IAEA/Pub1462_web.pdf%0Ahttp://www.ncbi.nlm.nih.gov/pubmed/16168243
ICRP. Radiation and your patient - A Guide for Medical Practitioners. ICRP Supporting Guidance 2. ICRP. 2001;31(4). doi:10.1016/0146-6453(81)90127-5
Martin CJ, Abuhaimed A, Lee C. Dose quantities for measurement and comparison of doses to individual patients in computed tomography (CT). J Radiol Prot. 2021;41(4):792-808. doi:10.1088/1361-6498/abecf5
Wang L, Li Q, Wang XM, et al. Enhanced radiation damage caused by iodinated contrast agents during CT examination. Eur J Radiol. 2017;92(October 2016):72-77. doi:10.1016/j.ejrad.2017.04.005
Sahbaee P, Abadi E, Segars WP, Marin D, Nelson RC, Samei E. The effect of contrast Material on radiation Dose at CT: Part II. A Systematic Evaluation across 58 Patient Models1. Radiology. 2017;283(3):749-757. doi:10.1148/radiol.2017152852
Frija G, Damilakis J, Paulo G, Loose R, Vano E. Cumulative effective dose from recurrent CT examinations in Europe: proposal for clinical guidance based on an ESR EuroSafe Imaging survey European Society of Radiology (ESR) 6. Eur Radiol. Published online 2021:5514-5523. https://doi.org/10.1007/s00330-021-07696-1
Visweswaran S, Kanagaraj K, Joseph S, Perumal V. Medical imaging: Contribution toward background radiation and human exposure. J Radiat Cancer Res. 2018;9(4):177. doi:10.4103/jrcr.jrcr_27_18
Lee C. How to estimate effective dose for CT patients. Eur Radiol. 2020;30(4):1825-1827. doi:10.1007/s00330-019-06625-7
ICRP. Radiological Protection in Medicine. ICRP Publication 105. ICRP. 2007;6(37). doi:10.1016/0146-6453(81)90127-5
Trattner S, Halliburton S, Thompson CM, et al. Cardiac-Specific Conversion Factors to Estimate Radiation Effective Dose From Dose-Length Product in Computed Tomography. JACC Cardiovasc Imaging. 2018;11(1):64-74. doi:10.1016/j.jcmg.2017.06.006
Mahesh M. New Conversion Factors for Estimating Effective Doses During Cardiac CTA ∗. JACC Cardiovasc Imaging. 2018;11(1):75-77. doi:10.1016/j.jcmg.2017.07.007
Lee SK, Kim JS, Yoon SW, Kim JM. Development of CT effective dose conversion factors from clinical CT examinations in the Republic of Korea. Diagnostics. 2020;10(9):1-13. doi:10.3390/diagnostics10090727
American Association of Physicist in Medicine. The Measurement, Reporting, and Management of Radiation Dose in CT, Report No. 96 of AAPM Task Group 23 2008. Vol 96. American Association of Physicists in Medicin; 2021.
Refbacks
- There are currently no refbacks.
©2017 (onwards) Aliansi Fisikawan Medik Indonesia / Indonesian Association of Physicists in Medicine
Print ISSN: 2355-2727 | Online ISSN: 2355-2719